MEMBER COMPANY PROFILE: BRUGG PIPES

When district heating assets pass the 20-year mark, age can easily become a proxy for conditions. Yet replacing pipes simply because they are old may remove assets that still have decades of useful life. A long-term assessment by the independent Dutch testing institute KIWA shows how operating data, field samples and laboratory testing can give utilities a more reliable basis for renewal planning.

Published in Hot Cool, edition no. 6/2026 | ISSN 0904 9681 |

A pipe with history. The assessment examined the PEX service pipe in a CALPEX PUR-KING flexible pre-insulated system manufactured by BRUGG Pipes and in operation since 2000. Initiated by the system owner’s long-standing installation partner, the study focused on the remaining service life of one sampled pipe segment—not the condition of the entire network.

The result was notable. In a hydrostatic pressure test to ISO 1167-2, performed at 95°C and 4.6 MPa, new PEX pipe must withstand at least 165 hours. The pipe removed after more than two decades in service showed no failure after more than 1,000 hours.

No data, no forecast. KIWA’s service-life calculation used the installation’s recorded temperature and pressure history. The pipe had generally operated below its maximum design values of 95°C and 10 bar, limiting accumulated material stress. Under comparable future conditions, the tested segment was estimated to have more than 25 years of remaining service life.

Operation is the key lever. PEX ageing increases disproportionately with temperature, as reflected in service-life calculations using Miner’s rule and ISO 13760. Avoiding temperature peaks and lowering supply temperatures can therefore extend pipe life while also reducing heat losses—in existing networks as well as new ones. This makes systematic logging and archiving of operating data essential: without a reliable history, remaining-life estimates are far less robust.

Service life belongs to the system. A flexible pre-insulated pipe combines a PEX service pipe, insulation, an outer casing, and joints. Failures may originate at joints, through installation damage, or from moisture in the insulation rather than in the service pipe itself. The tested product had a declared insulation conductivity of 0.0199 W/m·K, but long-term network performance also depends on moisture protection, trench preparation, handling, jointing, and commissioning.

Flexibility can support reliability by allowing longer installation lengths and smaller bending radii, reducing the number of joints and potential weak points. But these advantages only translate into longer service life when installation quality matches material quality. For asset owners, mechanical strength, thermal efficiency and the condition of the complete system must therefore be assessed together.

From one sample to better decisions. One tested segment cannot establish a universal lifetime for flexible pipe systems. Material formulation, installation quality, soil conditions, joints and operating profiles vary across a network. A broader assessment requires representative sampling and knowledge of any unusual temperature or pressure exposure.
Even so, the case demonstrates a practical method for evidence-based asset management. Instead of treating age as condition, utilities can combine operating records, inspections, representative field samples and targeted laboratory tests. The result is a more realistic picture of remaining service life and a stronger basis for prioritising maintenance and capital investment.

A sector-wide evidence gap. First-generation flexible networks are now reaching an age when renewal questions become pressing, yet systematic field data remain limited. Sharing anonymised test results through industry associations could help utilities compare experience, improve assumptions and make better-informed decisions.

Longer use is sustainability. Every premature replacement avoided saves pipe material, civil works, disruption and embodied emissions. Procurement and renewal strategies should therefore consider life-cycle cost and verified condition—not purchase price or calendar age alone.
The lesson from this single pipe is not that all PEX systems will perform identically. It is that assumptions can be replaced with knowledge. When utilities preserve operating data and test assets in the field, they can operate safely, invest more precisely, and capture the full value of infrastructure that may still have many years to give.

The Member Company profile for Brugg Pipes was published in Hot Cool, edition no. 6/2026. You can download the article here:

Did you find this article useful?

Subscribe to the HOT|COOL newsletters for free and get insightful articles on a variety of topics delivered to your inbox twice a month!